“At AltumSolutions, our mission is to revolutionize the food and agriculture sector by providing comprehensive solutions rather than mere spectrometers. We eliminate the need for specialized NIR-spectroscopy expertise, allowing our customers to focus on their core operations with peace of mind. Our commitment goes beyond producing cutting-edge devices; we develop and maintain calibration models, regularly validate accuracy, and furnish detailed reports. With AltumSolutions, you’re not just purchasing equipment; you’re investing in precision, reliability, and success.”
Solutions
We currently offer two near-infrared spectrometers: The M2000 for solids and the M2000T for fluids. Both devices are operated via an intuitive web app, which can be accessed with any modern end-user device such as iPads, iPhones, and Android systems.
M2000
The M2000 is a state-of-the-art NIR spectrometer with a wavelength range of 900-1700 nm. It measures absorption and reflection and works with solids. The device integrates a rotating disc that holds 90 mm petri dishes. It can measure up to 120 different spots of the same sample and thus adapt the measurement mode to the heterogeneity of the sample.
Specifications | |
---|---|
Wavelength Range | 900-1700 nm |
S/N Ratio | up to 20000:1 depending on measurement time |
Accuracy | +-1 nm |
Light Source | Tungsten-Filament Lamp |
Photodetector | Hamamatsu InGaAs photodiode |
Thermal Stability | 0.05 nm / K |
Optical Resolution | 10 nm |
M2000T
The M2000T covers the same wavelength range as the M2000 but is designed to work with fluids. It can be used with standard cuvettes and path lengths ranging from 1-10 mm.
Specifications | |
---|---|
Wavelength Range | 900-1700 nm |
S/N Ratio | up to 20000:1 depending on measurement time |
Accuracy | +-1 nm |
Light Source | Tungsten-Filament Lamp |
Photodetector | Hamamatsu InGaAs photodiode |
Thermal Stability | 0.05 nm / K |
Optical Resolution | 10 nm |
About
At AltumSolutions, Innovation Meets Integrity
AltumSolutions is a forward-thinking tech startup hailing from Erlangen, Germany, founded in 2022 by a trio of visionaries: Sebastian Kasanmascheff, Jonas Reubelt, Ph.D., and Minh Tran. We’re not just in the business of producing NIR and UV-VIS-NIR spectrometers; we’re crafting holistic service ecosystems. Our mission? To be the steadfast allies of the food and agriculture industry, tackling the complexities of food fraud and quality control head-on.
The Team
Meet the driving force behind AltumSolutions:
From left to right: Jonas Reubelt, Sebastian Kasanmascheff, Minh Tran
Sebastian Kasanmascheff (CEO and Initiator): An innovator and entrepreneur at heart, Sebastian brings his background in Forestry Science (Master of Science, University of Göttingen) and expertise in Remote Sensing and LiDAR Technology to the helm. Outside of AltumSolutions, he’s the founder of MapCad3D GmbH, a thriving drone survey company with over three years of successful operation.
Jonas Reubelt (Chief Data Analyst and Customer Success Operative): Jonas, our physics Ph.D., reigns as the authority in sensor-based data analysis. He crafts and validates calibration models, designs sampling strategies, and serves as the dedicated point of contact for all customer inquiries related to device measurements.
Minh Tran (User-Interface and Software Architect): Minh is the driving force behind our smooth user experiences. With more than 15 years of expertise in embedded software engineering, he boasts a profound grasp of device and server architecture, alongside a strong background in UI development.
Together, we serve our customers by implementing innovative technology, delivering a flawless customer experience, fostering loyalty, and upholding unwavering integrity.
Contact
Let us get in touch!
Imprint
AltumSolutions GmbH
Hutgraben 15
91058 Erlangen
Managing Partner: Sebastian Kasanmascheff
Commercial Register Entry HRB 19832 at the Local Court 90762 Fürth
VAT ID: DE331186902